Contents

Manitowoc ICE MACHINES amp REACH INS 7625573 FLARE NUT TXV REPLACEMENT Z200 Installation Instructions 1 Disconnect power from reach in 2 Recover refrigerant 3 Remove armaflex insulation from existing expansion valve 4 To remove expansion valve loosen flare nuts from expansion valve 5 Unsweat flare nuts extensions at solder joints 6 NOTE WRAP NEW TXV WITH WET CLOTH TO PREVENT OVERHEATING VALVE Slip copper extensions into TXV and swaged ends onto existing lines and sweat into place 7 When TXV is cool slip rubber boot over TXV and glue seam together 8 Evacuate and weigh in proper charge Manitowoc Ice Inc 2110 South 26 Street P O Box 1720 Manitowoc WI 54221 1720 USA Telephone 920 682 0161 Fax Sales 920 683 7589 Service ...